  5. \margr120
  6. \pard\tx960\tx1920\tx2880\tx3840\tx4800\tx5760\tx6720\tx7680\tx8640\tx9600\f3\b0\i0\ul0\fs24 timed entry event loop poll peek window server\
  7. \
  8. Q:  My timed entry does not seem to be happening when I use DPSPeekEvent().\
  9. \
  10. A:  Timed entries are executed only when getNextEvent: or DPSGetEvent() is called.  They will not be "triggered" by DPSPeekEvent().  A timed entry does not interrupt the current process; it will be executed the next time between events.\